In the Test Catalog, use the Specimen and Overview tabs of each test to identify:
Containers must be capable of withstanding, without leakage, an internal pressure of 95 kPa in the range of -40°C to 55°C.
Follow the instructions in the test to collect the specimen, paying special attention to container/tube, volume, and stability (temperature) requirements.
Specimens must have two person-specific identifiers on the patient label. Person-specific identifiers include:
Specimens are considered mislabeled when there is a mismatch between the person-specific identifiers on the specimen and the information accompanying the specimen. This information might include a computer system, requisition form, or additional paperwork.
In addition, if a handwritten name and a label are on the container, the information must match exactly. For example, "Rebecca" does not match "Becky." When insufficient or inconsistent identification is submitted, a new specimen may be required.
Place the tube or container in a Mayo Clinic Laboratories color-coded (temperature-specific) shipping bag.
T043 Biohazard Bag - 12x15 Use if your container is too large for color-coded bags. Mark it Frozen, Refrigerate, or Room Temp (Ambient).
Electronic Clients:
Folded batch sheet with bar code and delivery address visible
Clients who submit electronic orders will have a batch sheet. The bottom of the batch sheet lists the number of pages (for example, 1 of 3). Fold the batch sheets into fourths and place them in the outside pocket of the bag. If there is no pocket, place them inside the bag with the specimens. Include all pages in the corresponding bag. The delivery address and bar code, if applicable, must be visible. Do not combine multiple batches into one bag.
Clients who do not order electronically must include a completed Test Request form with each patient specimen. Fold and insert the completed form into the outside pocket of the biohazard bag. If there is no pocket, place the form inside the bag with the specimen.